27
!
#
"
$
&
%
Dust Extractor
RL 250 / RL 300 / RL 350
Setup and installation
!Cover
"/ #Potential-free contact
Potential-free contact
$Hole 1
%Hole 2
&Thumb screw
The unit can be connected via the potential-free contact
as follows:
"Woodworking machinery
#Warning alarm system
Connection to the dust extractor system:
1. Loosen the screw and take off the covering lid.
2. Potential-free contact connection
• Cut the wires to the same length.
• Insert into the holes 1 and 2 and push the plugs
together.
• Screw on the plug‘s thumb screw.
• The wires are automatically connected to the power
supply via an insulation displacement connector.
3. Mount the cover plate on again.
6.5.1 Potential-free contact
Warning! Danger! Electric current!
Work on electrical fittings may only be carried out by qualified personnel and in strict observance of the
safety instructions.
Fig. 6-8.1: Potential-free contact
Note:
Look at the enclosed wiring diagrams for further informa-
tion.