36
Dust Extractor
RL 250 / RL 300 / RL 350
8.2 Maintenance schedule
8.1 Safety instructions
8 Service
Warning! Risk of injury!
Improper maintenance can cause serious injury or damage. For this reason, this work may only be
carried out by authorised, trained personnel who are familiar with how to operate the machine and in strict
observance of all safety instructions.
Before beginning any maintenance work on the
machine, switch it off and secure it against acciden-
tally being switched on again.
Ensure that there is sufficient space to work around
the machine.
Keep the work area orderly and clean.
Components and tools that are not put in their cor-
rect place or put away may be the cause of acci-
dents!
Following the maintenance work, reinstall the guards
and check that they are functioning properly.
Note: Safety regulations
Notes are to be kept on the annual general revision. It must contain the inspection date, deficiencies found
and name of the inspector. (See inspection log in appendix)
The machine must, of course, be repaired if and when required!
Interval Task to accomplish
Daily Visual check whether unit or parts are damaged
Check whether power cable is damaged
Check whether dust bags are inserted
Fire extinguisher: Check display pressure
Check the compressed air supply
Monthly Visual check for leaks around filter (dust ejected from the unit cover)
Repair: Remove both filter plates and insert the new filters.
See chapter entitled >8.7 Changing the filter<
Check whether the minimum exhaust volume control is functioning correctly
Basic extractor: Check the extracter hood, clean if required
Twice a year Compressed air container visual check (for corrosion)
Empty the condensation receptable
Check whether the seal between dust collector and unit is broken, replace if needed
Annually Main inspection and air flow rate control *)
Every two years Extinguisher: The fire extinguisher must be checked by an authorized specialist company
*) We recommend this be performed by FELDER trained specialists.