–9
Optional Long Range Radio
¥ Allows all messages that have been programmed to go to the primary
telephone number to be reported additionally to a 7720PLUS or 7820
radio. Check availability of these models.
Built-in Telephone Line Monitoring Option
¥ The telephone line voltage can be monitored to supervise the phone line
connection. The panel must be connected to a proper earth
ground or you will get a false line cut indication if this feature
is enabled.
¥ The loss of the line can optionally cause a local display, or a display and
trouble sound.
Event Logging
¥ Event Logging feature keeps a record of selected events in a history log
(up to 48 events). All control and readout from the log is done via First
Alert Professional FADL software only.
Alarm Output
¥ Provides a 12VDC, 2 AMP output that can drive the compatible
sounders listed in the EXTERNAL SOUNDERS section (assumes a fully
charged battery is connected)
.
¥ Steady output for Burglary/Panic, or temporal pulse output (3 pulses Ð
pause Ð 3 pulses Ð pause Ð 3 pulses. . .) for Fire
¥ Uses current limiting circuitry for protection
Auxiliary Power Output
¥ Provides 12VDC, 600 mA maximum. Uses current limiting circuitry for
protection.
¥ This output interrupts for smoke detector reset if 4-wire smoke
detectors are used.
Programming
¥ Programmed options are stored in electrically erasable, non-volatile
EEROM memory (information can be reprogrammed at any time and
will not be lost in the event of a power loss).
¥ The system can be uploaded, downloaded, or controlled via an IBM
compatible computer, FADL software and a HAYES modem specified by
Ademco.
Keypad programming consists of:
¥ Data field programming
¥ Interactive (menu) mode programming
For programming from a keypad, a FA550KP 2-line Alpha keypad must be
connected to partition 1 (but need not necessarily stay in the system).
Communication Formats Supported
¥ Ademco Low Speed (Standard or Expanded)
¥ Sescoa/Radionics (Standard or Expanded)
¥ Ademco Express
¥ Ademco Contact ID
Zone Descriptors
You can assign Alpha descriptors to all zones (useful only when using
Alpha keypads and/or the FA4285 Phone Module).
AC Power Supply
Uses 1321, 110VAC plug-in transformer with 16.5VAC 25VA output,
unless Powerline Carrier devices (ex. X-10 type) are used, in which case a
4300 transformer module must be used.
Back-Up Battery
¥ Rechargeable (Gel type) 12VDC, 4AH minimum.

Table of Contents

Other manuals for First Alert FA162C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the First Alert FA162C and is the answer not in the manual?

First Alert FA162C Specifications

General IconGeneral
BrandFirst Alert
ModelFA162C
CategorySecurity System
LanguageEnglish

Related product manuals