PIOX S70x 6 Installation
34 UMPIOX_S7V4-6-3EN, 2018-10-10
6.4.3.4 Fixing the Rail to the Pipe
Place one tension strap clamp in the rail (see tension strap clamp 1 in Fig. 6.24). Observe the orientation of the tension
strap clamp.
Tighten the nut of tension strap clamp 1 slightly.
Screw the rail to tension strap clamp 2 (see Fig. 6.25).
Tighten the nut of tension strap clamp 2, but not too firmly in order not to damage the tension strap.
Select the installation instructions that correspond to the supplied clasp:
Band Clamp Clasp
Insert the tension strap into tension strap clamp 1 (see Fig. 6.26).
Place the tension strap around the pipe and insert it into the clasp (see Fig. 6.27).
Tighten the tension strap.
Tighten the screw of the clasp.
Tighten the nut of tension strap clamp 1, but not too firmly in order not to damage the tension strap (see Fig. 6.26).
Fig. 6.24: Rail with tension strap clamp
Fig. 6.25: Rail, mounted on one side of the pipe
Fig. 6.26: Rail on the pipe
Observe the
orientation!
nut
tension strap 1
nut
tension strap 2
tension strap 2
tension strap 1
nut
clasp
metal spring
tension
strap 1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Flexim PIOX S704 NN Series and is the answer not in the manual?

Flexim PIOX S704 NN Series Specifications

General IconGeneral
BrandFlexim
ModelPIOX S704 NN Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals