ULW transfer trailer
Use and operation
Fliegl Agrartechnik GmbH, 84453 Mühldorf am Inn, Germany
53 of 85
There must be no objects or persons within the danger area.
During unloading, there is a risk of injury due to the transferred load.
The main screw conveyor is powered by the towing vehicle via the PTO through drive
at a PTO speed of around 600 rpm.
The drive power is transferred from the PTO to the inclined screw conveyor via an
angle gear.
Indicator for dosing feeder (slide gate)
This indicator shows the position of the hydraulic slide gate.
Visible = open
Not visible = closed
Important:
The slide gate must be closed in good time so that the truck to be
filled is not overloaded. The time required for the inclined screw
conveyor to run empty must also be taken into account.
(Approx. 3 min. overrun time)
Fig. 55: Slide gate indicator
An overrun time of 3 minutes should be allowed before retracting the inclined screw
conveyor. Otherwise the bearing may extend out of the folding opening.
This also ensures that the transfer trailer is fully emptied and none of the load is lost.