12-13
FOR TRAINING PURPOSES ONLY
LEARJET 45 PILOT TRAINING MANUAL
FlightSafety
international
DELTA P
PROTECTION AND WARNING
9.5 PSID
• Master Caution lights flash
• Amber CAS message "CAB DELTA P"
• Digital Delta P readout on CPC LCD display flashes
• Delta P readout on ECS page of the EICAS/MFD
changes color to amber and is boxed
9.7 PSID
• Max Delta P limiters open
9.9 PSID
(Manual)
• Master Caution lights flash
• Amber CAS message "CAB DELTA P"
• Digital Delta P readout on CPC LCD display flashes
• Delta P readout on ECS page of the EICAS/MFD
changes color to red and is boxed
- 0.5 PSID
• Master Caution lights flash
• Amber CAS message "CAB DELTA P"
• Digital Delta P readout on the CPC LCD display flashes
Table 12-4. PRESSURIZATION PROTECTION AND WARNING (DELTA P)