Type
Msg
W
C
C
C
C
C
C
C
W
A
A
A
A
W = Warning
C = Caution
A = Advisory
L R BATT OVHT Batt overheat > 70° C (160° F), autoshed batt OFF
L R GEN FAIL
Both generators failed
L R BATT OVHT
Batt overheat > 60° C (140° F)
EMER BATT LOW
EMER batt taking excessive charge
NOTE: Inhibited for 2 minutes after engine start.
EMER BUS VOLTS
IC-600 generated, emer volts < 22 or > 29.5 VDC
L R ESS BUS VOLTS
ESS volts < 22 or > 29.5 VDC
L R GEN AMPS HIGH
Gen amps > 300 ground & in flight
NOTE: Inhibited during cross generator start and
temporarily suppressed after engine start
L R GEN FAIL
Left or right generator failed
BUS TIE CLSD
L and R buses tied (auto or manual)
BUS TIE MANUAL L and R buses tied or untied manually by pilot
EXTERNAL POWER
Ext power cable connected to aircraft, 5 volts detected
L R ESS BUS FAULT
L R ESS BUS FAULT
The respective essential bus contactor has failed open
(in flight)
The respective essential bus contactor has failed open
(on the ground)
Table 2-2. CAS MESSAGE DATABASE AND LOGIC SUMMARY