7. With failure of electrical power to both
channels of the CPC while airborne:
A. The controller reverts to manual
mode.
B. MANUAL PRESS must be selected
to enable manual control.
C. The cabin will depressurize.
D. The cabin will go to maximum dif-
ferential pressure (9.7 psid).
8. What CAS annunciation should the crew
expect to see if MANUAL PRESS is se-
lected?
A. CABIN ALTITUDE (amber)
B. CABIN ALTITUDE (white)
C. CAB PRESS MAN (amber)
D. CAB PRESS MAN (white)
9. At what cabin altitude will the passenger
oxygen masks automatically deploy?
A. 8,750 +
200 feet
B. 9,500 +
200 feet
C. 10,000 +
200 feet
D. 14,500 +
250 feet
10. The cabin pressurization system auto-
matically switches to manual mode when-
ever:
A. Dual ADC failure occurs.
B. MANUAL PRESS switch has been
depressed.
C. Left or right BLEED failure.
D. Cabin pressure controller channel fail-
ure (primary or secondary).
11. After experiencing a dual generator fail-
ure inflight, the cabin pressurization sys-
tem:
A. Reverts to manual mode.
B. Is shut down and the emergency pres-
surization system is activated.
C. Is unaffected, as the cabin pressure
controller’s secondary channel is pow-
ered by the Emer Batt Bus.
D. Automatically opens both outflow
valves, regardless of the airplane al-
titude.
12-22