LEARJET 45 PILOT TRAINING MANUAL
16-46
FOR TRAINING PURPOSES ONLY
FlightSafety
international
CAS Message
Logic Summary
W = Warning
C = Caution
A = Advisory
* = Annunciation on MFD display only
Type
Msg
C
C
C
C
C
C
C
C
C
C
C
C
A
A
A
A
A
A
A
A
L R PFD CHECK
IC 1-2 OVHT
IC BUS FAIL
DU 3-4 OVHT
DU 1-2 OVHT
DAU 2A-2B FAIL
DAU 1A-1B FAIL
AHRS 1-2 OVHT
LBS/KGS CONFIG
IC 1-2 WOW INOP
IC 1-2 FAN FAIL
DU 3-4 FAN FAIL
DU 1-2 FAN FAIL
DAU B REV
DAU A REV
EICAS CHK*
AHRS 1-2 BASIC
L R DAU SYS MISCMP
L R DAU ENG MISCMP
AHRS 1, 2, or both overheat or shutdown
C
CNFG MISMATCH Config strapping between IM-600's does not agree
1A or 1B, or combination, DAU channel failed
2A or 2B, or combination, DAU channel failed
IC Bus invalid, or off-side IC-600 failure
IC-600 (1, 2 or 1 & 2) overheat, ( > 110°C)
DU 3, 4 or 3 & 4 overheat > 120°C
DU 1, 2 or 1 & 2 overheat > 120°C
L or R PFD is displaying incorrect data
DAU engine miscompare logic (N1, N2 & ITT)
AHRS 1 or 2, or both reverted to basic mode
DAU misc. systems miscompare logic
EICAS display data may be corrupted
DAU reversion switch on Channel A
A
CKLST MISMATCH Different checklists loaded into each IC-600
DAU reversion switch on Channel B
DU 1, 2 or 1 & 2 cooling fan failure
DU 3, 4 or 3 & 4 cooling fan failure
IC-600 1 or 2, or 1 & 2 cooling fan failure
A
IC 1-2 CONFIG FAIL
Communication failure between IC-600 and IM-600
Validity monitor detects IC-600 WOW fault
Error between IC-600 and DAU strap config.
LBS/KGS CONFIG
Error between IC-600 and DAU strap config.
A
INSTR PNL TEMP
Thermal switch in instrument panel > 135° F
A
NOSE BAY TEMP
Thermal switch in nose avionics bay > 158° F
Table 16-2. AVIONICS CAS MESSAGES

Table of Contents