1750
Operators Manual
2
Automatic disturbance capture
The Recorder uses an automatic, self-learning threshold routine, which means you do
not have to set any event threshold limits before you start recording. You detect and
display power quality events (disturbances) using the Power Analyze software on a
PC after the event has been captured. You define thresholds for events after data is
stored on the PC. This is called the "event detector" in the software. It does not make
permanent changes to the data file, so you can experiment with different thresholds
after the fact without worrying about losing data.
With these features, there is little else required to set up and start recording the data to
conduct a power quality survey. Should you want to extensively analyze collected data,
the procedures described later in this manual review the transfer of data from the
Recorder to the PDA, and finally to a PC. Data may then be analyzed using Power
Analyze on a PC. Extensive online help is provided in the Power Analyze software on the
product CD shipped with the Recorder.
Contacting Fluke
To contact Fluke, call one of the following telephone numbers:
Technical Support USA: 1-800-44-FLUKE (1-800-443-5853)
Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853)
Canada: 1-800-36-FLUKE (1-800-363-5853)
Europe: +31 402-675-200
Japan: +81-3-3434-0181
Singapore: +65-738-5655
Anywhere in the world: +1-425-446-5500
Or, visit Fluke's website at www.fluke.com
.
To register your product, visit http://register.fluke.com
.
To view, print, or download the latest manual supplement, visit
http://us.fluke.com/usen/support/manuals
.
To contact Technical Support: fpqsupport@fluke.com
or 888-257-9897

Table of Contents

Other manuals for Fluke 1750

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 1750 and is the answer not in the manual?

Fluke 1750 Specifications

General IconGeneral
TypePower Quality Analyzer
Frequency Measurement Range42.5 Hz to 69 Hz
Safety RatingCAT IV 600 V, CAT III 1000 V
Accuracy±0.1% of reading
HarmonicsUp to 50th harmonic
CommunicationEthernet, USB
Power Supply100 V to 240 V AC
Channels4 voltage, 4 current
Battery BackupYes, internal battery
Measurement ParametersVoltage, Current, Power, Harmonics, Flicker
Data Logging Interval1 second to 60 minutes
Battery Life45 minutes (UPS)
Voltage Measurement Range1 to 1000 V (phase to neutral)
Operating Temperature-10 to 50 °C