EasyManuals Logo

Fluke 1750 User Manual

Fluke 1750
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
1750
Operators Manual
ii
Setting Up the Recorder..................................................................................... 38
Setting the Clock ........................................................................................... 40
Probe Detect .................................................................................................. 40
Setting the IP Address ................................................................................... 41
Adding a Measurement Description.............................................................. 41
Configure Nominal Power Values................................................................. 42
Using Phase Swap ......................................................................................... 42
Setting the Volts and Current Ratio............................................................... 43
Assign Recorder Name and Password........................................................... 43
Setting the Snapshot Period - Periodic Waveform Capture Setting .............. 44
Change Display Language and Phase Identifier............................................ 45
Working with Annotations ............................................................................ 45
Using Image or Voice Annotations........................................................... 47
Inserting Image or Voice Annotations ...................................................... 47
Turn off the Recorder ........................................................................................ 48
Cleaning and Maintenance................................................................................. 48
Regulatory Information for Wireless Communication ...................................... 49
Specifications for the System: Recorder and Power Analyze Software ............ 50
General Specifications................................................................................... 50
Input Specifications ....................................................................................... 50
Synchronization and Sampling...................................................................... 50
Voltage and Current Measurements .............................................................. 50
Voltage and Current Measurement Accuracy ............................................... 51
Transient Voltage (Impulse).......................................................................... 51
Dip (Sag) and Swell Measurements .............................................................. 51
Power and PF Measurement.......................................................................... 51
External Interface Specifications................................................................... 52
Environmental and Safety Specifications...................................................... 52

Table of Contents

Other manuals for Fluke 1750

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 1750 and is the answer not in the manual?

Fluke 1750 Specifications

General IconGeneral
TypePower Quality Analyzer
Frequency Measurement Range42.5 Hz to 69 Hz
Safety RatingCAT IV 600 V, CAT III 1000 V
Accuracy±0.1% of reading
HarmonicsUp to 50th harmonic
CommunicationEthernet, USB
Power Supply100 V to 240 V AC
Channels4 voltage, 4 current
Battery BackupYes, internal battery
Measurement ParametersVoltage, Current, Power, Harmonics, Flicker
Data Logging Interval1 second to 60 minutes
Battery Life45 minutes (UPS)
Voltage Measurement Range1 to 1000 V (phase to neutral)
Operating Temperature-10 to 50 °C