Fluke 192/196/199
Users Manual
96
Amperes (AMP)
With Optional Current Probe or Current Shunt
Ranges........................... same as VDC, VAC, VAC+DC
Probe Sensitivity................100 µV/A, 1 mV/A, 10 mV/A,
100 mV/A, 1 V/A, 10 V/A, and 100 V/A
Accuracy ........................ same as VDC, VAC, VAC+DC
(add current probe or current shunt accuracy)
Recorder
TrendPlot (Meter or Scope)
Chart recorder that plots a graph of min and max values
of Meter or Scope measurements over time.
Measurement Speed...................> 2.5 measurements/s
Time/Div.......................................10 s/div to 20 min/div
Record Size................................ 13500 points per input
Recorded Time Span...........................90 min to 8 days
Time Reference...................time from start, time of day
Scope Record
Records scope waveforms in deep memory while
displaying the waveform in Roll mode.
Source...................................................Input A, Input B
Max. Sample Speed (10 ms/div to 1 min/div).....20 MS/s
Glitch capture (10 ms/div to 1 min/div) .................. 50 ns
Time/Div in normal mode ............. 10 ms/div to 2 min/div
Record Size.................................27500 points per input
Recorded Time Span ............................11 s to 30 hours
Acquisition Modes.....................................Single Sweep
Continuous Roll
External Triggering
Time Reference ...................time from start, time of day