Accessory Information
Current Shunt (80J-10)
6
6-9
kHz to 700 MHz
RESPONSE....................................... Responds to the peak value of an
input and is calibrated to read rms
value of a sine wave.
VOLTAGE RANGE ......................... 0.25 to 30V rms
MAXIMUM INPUT VOLTAGE...... 30V rms, 200V dc
INPUT CAPACITANCE .................. Approximately 3 pF
TEMPERATURE RANGE
Operating.........................................
Storage ............................................
+10
°
C to +35
°
C
40
°
C to +75
°
C
HUMIDITY ...................................... <90% R.H
OUTPUT CONNECTOR.................. Fits standard 0.75-inch dual banana
connectors
6-9. Current Shunt (80J-10)
The Model 80J-10 Current Shunt extends the current measuring capability of
the DMM to 10 amps continuous (20 amps for periods not exceeding one
minute) dc to 10 kHz at an accuracy of
±
0.25% in excess of the voltmeter
accuracy.
SHUNT ............................................. 10 amps at 100 mV
ACCURACY (18
°
C to 28
°
C)
DC to 10 kHz ..................................
10 kHz to 100 kHz ..........................
±
0.25%
Rising to 1 dB at 100 kHz typical
TEMPERATURE COEFFICIENT ... 0.005%/
°
C
INDUCTANCE................................. 18.3 nH in series w/0.01
shunt
OVERLOAD..................................... Up to one minute at 20A with a 1/4
duty cycle for recovery after currents
between 10A and 20A.
CONNECTS TO ............................... 3/4 inch center banana jacks
CONNECTORS................................ 5-way binding posts (red and black)
6-10. AC/DC Current Probe (Y8100)
The Fluke Y8100 AC/DC Current Probe is a clamp-on probe that is used
with a voltmeter, multimeter, or oscilloscope to read dc, ac or composite (ac
on dc) current measurements. The jaws on the Y8100 are designed to clamp

Table of Contents