EasyManua.ls Logo

Fluke DTX-GFM2 - Coaxial Autotest Results

Fluke DTX-GFM2
320 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Certifying Coaxial Cabling
Coaxial Autotest Results
5-9
5
Coaxial Autotest Results
Figure 5-5 describes the Autotest Summary screen, which
lists the tests that apply to coaxial cabling.
Note
The Autotest runs some or all of the tests shown in
Figure 5-5, depending on the selected test limit.
Figure 5-5. Autotest Results for Coaxial Cabling
amd141f.eps
A
PASS: All parameters are within limits.
FAIL: One or more parameters exceeds the limit.
B
E: The test passed.
i: The parameter was measured, but has no PASS/FAIL limit in the
selected test limit.
X: The test faile.
C
The worst margin found for the test.

Table of Contents

Other manuals for Fluke DTX-GFM2

Related product manuals