EasyManua.ls Logo

Fluke DTX-GFM2 - Creating a Custom Outlet Configuration

Fluke DTX-GFM2
320 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Custom Test Settings
Creating a Custom Outlet Configuration
11-5
11
Creating a Custom Outlet Configuration
You can create up to nine custom outlet configurations. A
custom outlet configuration includes the following settings:
Custom outlet name
Baseline outlet configuration for default settings
Testing enabled or disabled for each wire pair
To create a custom outlet configuration:
1
Turn the rotary switch to SETUP; then select Tw is t ed
Pair.
2
Select Outlet Configuration; then select Custom.
3
Press J Create.
4
On the Custom screen, select Name; then use the text
editing screen to enter a name for your custom
configuration. Press
N when you are done.
5
On the Custom screen, select Use Default Values From;
then select an outlet configuration as a baseline for
your custom configuration.
6
On the Custom screen use AD and H to
select wire pairs to enable or disable.
7
If the baseline configuration has additional wire pairs,
use BC to move among the tabs.
8
From the Custom screen, press N when you are done
creating the outlet configuration.
The tester saves the custom configuration in the
Custom list, with asterisks (*) before and after the
name.