DTX Series CableAnalyzer
Technical Reference Handbook
7-46
To use the FindFiber function in Smart Remote mode:
1
Turn the rotary switch to SETUP; then select Fiber.
2
Select Remote End Setup; then select Smart Remote.
3
Clean all connectors; then make the connections
shown in Figure 7-22.
4
Turn the rotary switch to MONITOR; then select
FindFiber.
5
Try various connections to the patch panel with the
main tester’s INPUT fiber until the input fiber’s status
shows Connected.
6
Then try various connections with the main tester’s
OUTPUT fiber until the output fiber’s status shows
Connected.
Figure 7-23 shows the main tester results for Smart
Remote mode.