iTuner Manual
41
4.5.3 VSWR_INC command
Syntax:
VSWR_INC degrees
Parameter:
degrees
Return value:
Remarks:
Used after VSWR_INIT to increment phase by the specified amount. VSWR is kept
constant while adjusting phase
Examples:
4.5.4 VSWR_STEP command
Same as VSWR_INC
4.5.5 VSWR_DO360 command
Syntax:
VSWR_DO360 [Speedfactor]
Parameter:
SpeedFactor
May be used to reduce speed while moving carriage
Range: 0.1 to 1, default is 1 (normal speed)
Return value:
Remarks:
Used after VSWR_INIT to perform a full 360
o
phase sweep with maximum
horizontal motor speed while continuously adjusting vertical position to keep
VSWR constant.
Examples:
VSWR_DO360 0.5
Do a full 360degr VSWR phase sweep at half the
normal speed
4.5.6 VSWR_PHASE command
Syntax:
VSWR_PHASE offset
Parameter:
offset
Defines the phase offset from the VSWR_INIT position
Range: 0 to 360
Return value:
Remarks:
Used after VSWR_INIT to set the relative phase on the VSWR circle. Use instead

Table of Contents