Stop
cause #
Message
Description
87 No wire signal No wire signal
88 Move from wire Problem with the wire sensors readings
89 Start elsewhere Problem with the wire sensors readings
90 Move from wire
Problem with the wire sensors readings Perimeter wire might be
too close
91 Start elsewhere Problem with the wire sensors readings
92 Move from wire
Problem with the wire sensors readings Perimeter wire might be
too close
93 Start elsewhere Problem with the wire sensors readings
94 No wire signal No wire signal
95 No wire signal No wire signal
96 Recharge batt. Battery needs recharging
98 Start elsewhere Software problem
100 Check mow height Mowing motors problem
101 Mowing Overload Mowing motors overload
102 Drive overload Drive motors overload
103 Start elsewhere Problem with the wire sensors readings during Edge
107 Start elsewhere Failure of the Wire Rescue maneuver
109 Start elsewhere Software problem
113 Replace lamp Replace lamp
114 Thermistors fail Thermistors failure
115 Bumper disc. Bumper disconnected
116 Bumper disc. Bumper disconnected
117
‘Button name’
pressed
One of the remote’s buttons is pressed during power up
118 Start elsewhere Problem with the wire sensors readings
119 Rain detected Rain detected
120 Replace blades Replace blades
121 Docking problem Robot did not succeed disconnecting from the docking
122 Docking problem
Edge process was terminated before we reached the docking
station because perimeter island was detected
123 Docking problem
Edge process was terminated before we reached the docking
station because we reached the required DK quarters
124 Docking problem Software problem
125 Docking problem
Edge process was terminated before we reached the docking
station because we reached the required edge distance that was
set by the user in this Zone
126 Docking problem
Edge process was terminated before we reached the docking
station because we reached the required DK quarters
5