Service Bulletin #RL0536-11
Technical Service Bulletin
Date:
Sep 20, 2005
Part Numbers:
All Software Version
Product Model:
All
Countries Affected:
All
Serial Range:
All
S.W. version (Flash) Replacement Instructions
The following instructions are in addition to the standard procedure defined in the Service Guide.
Spare Part
Flash
(S.W. version)
When to use?
Main Board
Manual
Controller
SPP0033C/35C/
36C/40C/41C
3.2-06
The most updated S.W version for
RL850 - compatible with Main Board
ESBC050B
SPP0019B
Main Board label
is marked with
ESBC050B
All
SPP0101A-
105A
4.1-06
The most updated S.W version for
RL1000 - compatible with Main Board
ESBC050B
SPP0019B
Main Board label
is marked with
ESBC050B
All
SPP0027A
3.2a
The most updated S.W version
compatible with Main Board
ESB0019B/C.
Main Board label
is marked with
ESB0019B/C
MSB0112A
MSB0114A
(Does not support
MSB0117A to
MSB0019A)
PRG0005A
3.2i
(Service
Bulletin
#RL0305-07)
Service version supporting Main Board
ESBC045B only (especially for
‘Charging failure’ message received
during the charging process)
Main Board label
is marked with
ESBC045B
MSB0112A
MSB0114A
(Does not support
MSB0117A to
MSB0019A)
NOTE: After replacing a flash (S.W version) it is required to perform the following steps:
1. 'Factory defaults' under the 'Service>Settings' menu.
2. The mower will display 'Are you sure?’ - Press the ‘GO’ button to confirm (it will reset).
3. Under 'Service' perform 'Learn wire sensors' (Section 5.3.4 in the Service Guide)
4. Under 'Service' perform 'Edge Calibration' (Section 5.3.3 in the Service Guide)
5. Under 'Service' perform ‘Set country' (Section 5.3.1 in the Service Guide).
6. Under 'Service' perform ‘DK Calibration’ (Section 5.3.2 in the Service Guide).
7