VIBRATORY SIEVE SHAKER
ANALYSETTE 3
Operang
instrucons
Valid starng with: 03.X020/2019
Read the
instrucons prior to performing any task!
Translaon of the original operang instrucons

Table of Contents

Questions and Answers

  • J
    Jessica PerryAug 3, 2025
    What to do if the POWER light does not light up on my Fritsch ANALYSETTE 3 Laboratory Equipment?
    • R
      Richard AdkinsAug 3, 2025
      If the POWER light on your Fritsch Laboratory Equipment isn't lighting up, here's what you can check: * Ensure the mains plug is properly connected. * Verify that the main switch is turned on. * Inspect and replace the mains fuse if it's blown. * Check the line fuse of the mains socket and switch it on or replace the fuse in the fuse box.
  • M
    Michael SchultzAug 10, 2025
    Why is the sieving stock not dispersed evenly on the sieve surface in my Fritsch ANALYSETTE 3 Laboratory Equipment?
    • S
      Scott CannonAug 10, 2025
      Uneven dispersion of sieving stock on the sieve surface of your Fritsch Laboratory Equipment can occur due to: * Unevenly tightened toothed belt: Ensure the toothed belt is tightened evenly. * The device not being level: Level the device by adjusting the feet. * Old sieves with deformed mesh wire: Replace the sieve if the mesh wire has no tension.
  • R
    Rebecca MartinezAug 17, 2025
    What to do if I observe large control fluctuations around the set point in my Fritsch Laboratory Equipment?
    • G
      gabrielgordonAug 17, 2025
      Large control fluctuations around the set point in your Fritsch Laboratory Equipment can be caused by: * A loose sieve stack: Tighten the toothed belt. * Loose screws on the laminated spring assembly: Re-tighten the screws to 8Nm. * Defective flat springs: Check the flat springs for tears and replace the laminated spring assembly if needed. * Overheated flat springs: Allow the springs to cool down.
  • X
    xyoungAug 26, 2025
    How to fix rattling noises in Fritsch ANALYSETTE 3?
    • R
      Renee AcevedoAug 27, 2025
      Rattling noises in your Fritsch Laboratory Equipment may be due to: * A loose tension belt: Tighten the tension belt. * An amplitude exceeding 3 mm: Set the amplitude to less than 3 mm.

Summary

Safety Information and Use

Requirements for the User

Defines who can operate and maintain the ANALYSETTE 3, emphasizing trained personnel.

Operating Principle

Explains the electromagnet and vibratory system of the ANALYSETTE 3.

Protective Equipment

Highlights the importance of using and maintaining protective equipment.

Electrical Safety

Details general electrical safety, protection against restart, and overload protection.

Hazards and Symbols

Explains hazard symbols and safety information designations used in the manual.

Technical Data

Dimensions and Weight

Provides physical specifications like dimensions (350x200x400mm) and net weight (21kg).

Voltage and Power

Details operational voltage ranges (115V/230V) and power consumption (approx. 50W).

Sieve Mesh Widths

Lists applicable sieve mesh widths for dry, wet, and micro sieving.

Installation

Setting Up

Guidance on placing the device on a stable surface and leveling it.

Electrical Connection

Procedures for connecting the device to the power supply and adjusting mains voltage.

Initial Start-up

Switching On and Function Check

Steps to power on the device and verify its operational status.

Using the Device

Sieving Process Overview

Covers fitting sieves, clamping, and the general sieving procedure.

Dry Sieving

Details parameters, aids, and procedures for dry sieving.

Wet Sieving

Explains procedures, parameters, wetting agents, and precautions for wet sieving.

Micro-Precision Sieving

Instructions for using the ANALYSETTE 3 PRO for high-precision sieving.

Setting Sieving Parameters

Guides on setting sieving time, amplitude, interval time, and saving settings.

Accessories

AUTOSIEVE Program

Information on the software for automatic evaluation of sieving results.

TorqueMaster Clamping

Details the TorqueMaster for faster and more accurate sieve clamping.

Cleaning

Cleaning the Device and Sieves

Instructions for cleaning the device and test sieves.

Maintenance

TorqueMaster Clamping Device Maintenance

Covers the maintenance and cleaning of the TorqueMaster clamping unit.

Repairs

Troubleshooting Checklist

A guide to identify and resolve common faults and issues with the device.

Guarantee Terms

Guarantee Conditions and Loss

Outlines warranty terms, claims, and conditions that void the guarantee.

Exclusion of Liability

Safety Logbook

Fritsch ANALYSETTE 3 Specifications

General IconGeneral
Sieve Heightup to 50 mm
Sieve Diameter200 mm / 8"
Timer1 - 99 min
Operating ModeContinuous or interval operation
Voltage230 V, 50/60 Hz