5 | FAQ
102 B1820023_en | Service handbook Lambdatronic H 3200 - T4e
5.5.2 “Automatic” mode with storage tank
When “Automatic” is selected with storage tank, the boiler only produces heat if the storage tank actually
requests heat within the specified storage tank loading time. Outside these times the boiler is in “Standby"
status.
The heating times should be set within the storage tank loading times so that the provision of heat is guaranteed
over the entire heating time.
Note that the heating circuit and DHW tank are only supplied with heat for as long as the storage tank
temperature is sufficient for the demand.
Example 1: “Automatic” mode with storage tank
Storage tank loading time 1
Heating time 2
Heating time 1
setback mode
DHW tank loading time 1
DHW tank loading time 2
Tip: In systems with a storage tank and solar panels, choose the storage tank loading time so that solar
energy can be used.
In order to ensure that there is sufficient heat at the start of the DHW tank loading time and heating time, we
recommend setting the storage tank charging time to begin before the start of the DHW tank time or heating
time.
Example 2: “Automatic” mode with storage tank and solar panel system
Storage tank loading time 1
Heating time 2
Heating time 1
setback mode
DHW tank loading time 1
DHW tank loading time 2