Parameters overview | 4
B1820023_en | Service handbook Lambdatronic H 3200 - T4e 71
4.11 Difference regulator
4.11.1 Difference regulator - Status
System menu Difference regulator
Heat source temperature
Display of the current heat source temperature of the
differential controller (e.g. tiled stove with water pocket,
…).
Heat sink sensor
Display of the current temperature of the heat sink for the
differential controller (e.g. layered tank, etc.).
Pump speed
Specifies the current speed of the differential controller
pump.
4.11.2 Difference regulator - Temperatures
System menu Difference regulator
Startup differential
Temperature difference between heat source and heat
sink which must be reached to activate the pump of the
differential controller.
Shutdown differential
If the temperature difference between the heat source and
the heat sink falls below this value, the pump of the
differential controller is deactivated.
Minimum temperature for heat source
If the temperature in the heat source falls below this value
the differential controller will be deactivated.
Maximum temperature for heat sink
When the heat sink reaches this value, the pump of the
differential controller is deactivated.
4.11.3 Difference regulator - Times
System menu Difference regulator
Ü "Setting times" [}106]

Table of Contents

Other manuals for Froling T4e

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Froling T4e and is the answer not in the manual?

Froling T4e Specifications

General IconGeneral
BrandFroling
ModelT4e
CategoryBoiler
LanguageEnglish

Related product manuals