4 | Parameters overview
42 B1820023_en | Service handbook Lambdatronic H 3200 - T4e
4 Parameters overview
4.1 Heating
4.1.1 Heating - Status
System menu Heating
Heating circuit mode
Display and setting the heating circuit mode:
Auto:
Automatic: heating phases according to the set
heating times
Extra heating:
The heating circuit is regulated to the set room
temperature with no time limitation. To cancel this
function, activate another mode/function
Setback:
Setback mode; the current or next heating phase
is ignored
Continuous setback mode:
Heating circuit remains in setback mode until
another mode is activated
Party:
Party mode; the current or next setback phase is
ignored
Heating circuit mode
OFF:
Switched off; heating circuit deactivated, only frost
protection!
Actual flow temperature
Display of the current flow temperature.
Room temperature
Prerequisite: Heating circuit used in conjunction with
remote control
Display of the current room temperature.
Outside air temperature
Display of the current outside air temperature.
4.1.2 Heating – Temperatures
System menu Heating
Desired room temperature during heating mode
Prerequisite: Heating circuit used in conjunction with
remote control
Room temperature which is regulated during the set
heating times.
Desired room temperature during setback mode
Prerequisite: Heating circuit used in conjunction with
remote control
Room temperature which is regulated outside of the set
heating times.
Flow temperature SP at outside air temperature of
+10°C
First setting point for definition of heating curve.