8
Press the info button to display the parameters in the following sequence:
Retrieving para-
meters during
charging
Example: current battery
voltage
Example: current charging
current
Example: ampere-hours
already charged
Important! The charger automatically switches over to conservation charging after
approx. 1-7 hours, depending on the type of battery. To charge the battery completely,
the battery should remain connected to the charger for this length of time.
3. When the battery is fully charged, the charger begins conservation charging.
- Display shows 4 bars
- Battery is now ready for use
- All bars are displayed
- The battery is 100 % charged
- Battery is always ready to use
- Battery can remain connected to charger for as long
as required
- Conservation charging counteracts battery self-
discharge
1. During charging, the number of bars indicates how charging is progressing.Charging
2. Final charging stage - once the battery is approx. 80-85 % charged
2. Ensure charging terminals are connected to correct polesStarting charging
manually (deep-
discharge batte-
ry)
(continued)
3. Starting charging
NOTE! During charging, increased demand for current can lead to a drop in
battery voltage (e.g. switching on additional consumer loads). To compensate
for this, the charger can increase the current briefly to the set device current.
If there is no confirmation of correct pole connection within 10 secs, the device
reverts to menu mode.