19
Mains voltage (+/- 15%)
Acctiva Professional Flash 230 V AC, 50/60 Hz
Acctiva Professional Flash UCN 115 V AC, 50/60 Hz
Acctiva Professional Flash JP 100 V AC, 50/60 HZ
Nominal output max. 1080 W
Charging voltage 12.0 - 15.5 V
Charging current I
2
(adjustable) 2 - 50 A
Boost mode charging current t
2 max
(tI
2 max
= 30 s, tI
2
= 60 s) max. 70 A
Nominal charging capacity 10 - 250 Ah
Number of cells 6
Duty cycle (I
2
= 50 A) 40°C (104°F) 100 %
50°C (122°F) 50%
60°C (140°F) 20%
Charging characteristic IUoU / IUIoU / IU
Operating temperature* 0°C to +60°C
32°F to 140°F
Storage temperature -20°C to +80°C
4°F to 176°F
Interface USB
Climate class (EN50178) B
EMC class
Acctiva Professional Flash IEC/EN 61000-6-4/2 (EMC class A)
Acctiva Professional Flash UCN FCC Part 15 (EMC class A)
Acctiva Professional Flash JP IEC/EN 61000-6-4 (EMC class A)
Protection IP 21
Marks of conformity see rating plate
Weight inclusive of mains and charger leads 6.5 kg
14.33 lb.
Dimensions w x h x d 315 x 200 x 110 mm
12.40 x 7.87 x 4.33 in.
* If the ambient temperature rises to above 35°C (95°F) or thereabouts (depending on
secondary voltage), the secondary output current is reduced (power derating)
Technical data
Nothing on display
Cause: Mains supply interrupted
Remedy: Connect mains supply
Cause: Mains plug or mains cable faulty
Remedy: Replace mains plug or mains cable
Cause: Charger faulty
Remedy: Contact specialist dealer
Charger does not start charging
Cause: Charging terminals or charger lead faulty
Remedy: Replace charging terminals or charger lead
(M8 nut torque = 15 Nm)
Troubleshooting
(continued)
Acctiva Professi-
onal Flash /
Acctiva Professi-
onal Flash UCN /
Acctiva Professi-
onal Flash JP