12
Setup menu
General remarks The setup menu gives you the ability to configure the device’s basic settings according
to your own requirements. You can also store frequently used charge settings.
Accessing setup
menu, overview
2. Select menu item
1. To access menu: press info button for approx. 5 secs
User U/I
Stores user settings for current and voltage
(end-of-charging voltage, charging current, floating voltage,
max. charging period, etc.)
3. Access the submenu
PREFERRED SETTINGS
Saves the frequently used operating modes you wish to keep
once the charger leads are removed or the charger is discon-
nected from the mains.
FACTORY SETTING
Resets device to factory setting
DELAY TIME
Sets the charging start delay time. Charging starts after a
predefined period.
DEVICE VERSION
For querying the current hardware and firmware version
EXIT SETUP
Exits the setup menu
Important! If no selection is made within 30 seconds, the setup menu is exited automati-
cally.
WARNING! Operating the equipment incorrectly can cause serious damage.
The functions described must only be carried out by trained and qualified
personnel. In addition to the safety rules in these operating instructions, the
safety rules of the battery and vehicle manufacturers must also be followed.
CHARGING CABLE
Settings defining the length and cross-section of the charging cable