EasyManua.ls Logo

Fronius Acctiva Professional Flash - Troubleshooting

Fronius Acctiva Professional Flash
296 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18
Troubleshooting
Troubleshooting
Charging terminals connected to wrong poles
Cause: Charging terminals connected to wrong poles
Remedy: Swap charging terminals round
Charging terminals short-circuited
Cause: Short-circuit on the charging terminals
Remedy: Rectify short-circuit on the charging terminals
Cause: Battery not detected
Remedy: Check that charging terminals are properly connected, press Start/Stop
button for 5 seconds
Over-temperature
Cause: Over-temperature - charger too hot
Remedy: Allow charger to cool down
Cause: Air inlets and outlets covered
Remedy: Ensure air inlets and outlets are not obstructed
Safety cut-out
Cause: Battery faulty
Remedy: Check battery
Cause: Charger incorrectly set
Remedy: Check settings: Ah, voltage
Cause: Incorrect battery type (e.g. NiCd), incorrect number of cells (voltage)
Remedy: Check battery type
Fan blocked/faulty
Cause: Fan blocked
Remedy: Check air inlet, remove foreign bodies if necessary
Cause: Fan faulty
Remedy: Contact specialist dealer
Charger faulty
Cause: Charger faulty
Remedy: Contact specialist dealer

Table of Contents

Other manuals for Fronius Acctiva Professional Flash

Related product manuals