Electrolyte circu-
lation
Electrolyte circulation "Air Pump"(not avail-
able with the Selectiva 220 V version):
The sequential control of the electrolyte
circulation takes place via the battery char-
ger control unit. Several selection options
are available for this purpose.
The following settings are available for the electrolyte circulation:
Off
- Electrolyte circulation switched off.
Continuous
- Electrolyte circulation constantly switched on.
Program 1 to 5
- Factory-set programs for the electrolyte circulation and their relevant parameters
can be found in the table in the "Settings" section of the "Display" chapter.
Automatic
- Automatic adjustment of the flow rate of the electrolyte circulation based on the set
battery parameters.
User "On"/"Off"
- Individual setting for the electrolyte circulation.
- The "On" and "Off" settings determine the pulse/pause ratio of the airflow intervals.
Factory-set programs for the electrolyte circulation and the relevant parameters are
shown in the table below:
Program ON 1 OFF 1 Repeat ON 2 OFF 2
1 30 min 25 min 1 x 5 min 25 min
2 3 min 10 min 4 x 3 min 20 min
3 3 min 12 min 1 x 3 min 12 min
4 5 min 10 min 3 x 5 min 20 min
5 2,5 min 7,5 min 1 x 2,5 min 7,5 min
In each of these programs, the solenoid valve picks up for an "ON 1" time and drops out
for an "OFF 1" time. This process repeats as many times as specified for "Repeat". After
this number of repetitions has elapsed, the "ON 2" and "OFF 2" times continue until the
end of charging.
Temperature-con-
trolled charging
Temperature-controlled charging:
37