The following settings are available for temperature-controlled charging:
automatic/OFF/required
- automatic ... Temperature-dependent adjustment of the charging characteristic.
- OFF ... The measured battery temperature is not taken into account.
- required ...
Charging only starts when the temperature sensor is connected.
Error overtemperature ON/OFF
- ON ... An error message is output in the event of a battery overtemperature.
The charging process stops and can only be continued after the battery has cooled
down and been reconnected.
- OFF ... No error message in the event of a battery overtemperature.
Warning overtemperature ON/OFF
- ON ... A warning is output in the event of a battery overtemperature.
- OFF ... No warning in the event of a battery overtemperature.
For certain curves, an external temperature sensor is required. If such a curve is selec-
ted in configuration mode, a message is displayed indicating that an external temperat-
ure sensor is required.
The following curves require an external temperature sensor:
- 28 - FCC IUI - CSM WET
- 30 - FCC IUI - WET
If a curve is selected that requires an ex-
ternal temperature sensor, a message ap-
pears.
1
Confirm the message by pressing the
"Pause/Start" button.
Equalizing
charge
Equalising charge