- Aquamatic
- Charging
- Charge 50 %
- Charge 80 %
- Charge Finish
- Main Charge Finished
- Charge OK
- Charge not complete
Signal if the battery is prematurely disconnected from the battery charger
- Cumulative Error
- Cumulative error + warning
- Signal Lamp
- Immobiliser
- ON
- Refill Indicator
- Battery Cold
- External air pump (electrolyte circulation)
Aquamatic The Aquamatic control includes the control of a solenoid valve for automated water re-
filling at the battery to be charged.
Standard setting
- At the beginning of the recharging phase, the solenoid valve picks up for 12
seconds, then the solenoid valve drops out for 4 seconds.
- This cycle repeats 26 times.
USER setting
- Adjustable "ON" time (solenoid valve picks up) after the end of the main charging
phase.
Charging The "Charging" option is suitable for controlling a signal lamp, for example. While char-
ging is in progress, the corresponding relay automatically picks up.
Charge 50 % In the same way as the "Main Charge Finished" function, the corresponding relay
switches as soon as the battery is charged to 50%.
Charge 80 % In the same way as the "Main Charge Finished" function, the corresponding relay
switches as soon as the battery is charged to 80%.
Charge not com-
plete
The "Charge not complete" option is suitable for controlling an acoustic signal generator,
for example. If the battery is disconnected from the battery charger before the charging
process is completed, the relay switches for an adjustable time of 1 to 10 seconds.
Charge Finish The "Charge Finish" option is suitable for controlling a signal lamp, for example. When
the configured charging characteristic is complete, the corresponding relay automatically
picks up.
59