Fronius TransTig 2200 - Engaged Calibration Service Codes

Fronius TransTig 2200
220 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cause: At maximum wire feed speed,
the motor of the push-pull unit
does not deliver any actual rota-
tional speed value.
Remedy: Repeat the push-pull calibra-
tion. If the error message re-
appears: Contact After-Sales
Service.
Cause: Push-pull calibration was inter-
rupted: Quick-stop was activ-
ated by pressing the torch trig-
ger.
Remedy: Repeat push-pull calibration
Service codes when the drive units are engaged (engaged calibration)
Cause: "Push-pull calibration - open-cir-
cuit" has not been carried out
Remedy: Carry out "push-pull calibration -
open-circuit"
Cause: At minimum wire feed speed,
the wire-feed unit motor does
not deliver any actual rotational
speed value.
Remedy: Repeat the push-pull calibra-
tion. If the error message re-
appears: Contact After-Sales
Service.
Cause: At minimum wire feed speed,
the motor of the push-pull unit
does not deliver any actual rota-
tional speed value.
Remedy: Repeat the push-pull calibra-
tion. If the error message re-
appears: Contact After-Sales
Service.