1. ETERNUS AX/HX Installation
Installation Specifications
Site Planning Guide10
*1: A 2U power distribution unit is composed of two 1U power distribution units.
Maximum
power
consumption
(*2)
Controller
shelf
2.5" type AC100 – 120V 507 W (518 VA) 528 W (539 VA) 1004 W
(1004 VA)
AC200 – 240V 497 W (508 VA) 518 W (530 VA) 1,079 W
(1,080 VA)
Drive shelf DS224C
2.5" type
AC100 – 120V - 390 W (398 VA) -
AC200 – 240V - 383 W (392 VA) -
NS224 AC100 – 120V - - 848 W (848 VA)
AC200 – 240V - - 848 W (848 VA)
Maximum configuration
(*4)
AC100 – 120V 507 W (518 VA) 2,478 W
(2,529 VA)
1852 W
(1852 VA)
AC200 – 240V 497 W (508 VA) 2,433 W
(2,490 VA)
1,927 W
(1,928 VA)
Maximum heat
generation
(*2)
Controller
shelf
2.5" type AC100 – 120V 1,825 kJ/h 1,901 kJ/h 3,614 kJ/h
AC200 – 240V 1,789 kJ/h 1,865 kJ/h 3,884 kJ/h
Drive shelf DS224C
2.5" type
AC100 – 120V - 1,404 kJ/h -
AC200 – 240V - 1,379 kJ/h -
NS224 AC100 – 120V - - 3,053 kJ/h
AC200 – 240V - - 3,053 kJ/h
Maximum configuration
(*4)
AC100 – 120V 1,825 kJ/h 8,921 kJ/h 6,667 kl/h
AC200 – 240V 1,789 kJ/h 8,759 kJ/h 6,937 kJ/h
Maximum
amount of
exhaust air
Controller shelf ---
Drive shelf 2.5" type / 3.5" type - - -
NS224 - - -
60-drive type - - -
Environmental
conditions
Tempera-
ture
Operating 5 – 45 °C (*5) 10 – 35 °C (*6)
Not operating -40 – 70 °C
During shipment -40 – 70 °C
Temperature gradient 15 °C/Hr or less
Humidity Operating (*5) 8 – 90 %RH
Not operating 10 – 95 %RH
During shipment 10 – 95 %RH
Humidity gradient 30 %/day or less
Maximum wet bulb temperature 29 °C
Altitude above sea level 0 – 3,048 m
Airborne dust
0.15 mg/m
3
or less
Gas concentration tolerance level Cl
2
: 6.8 ppb or less, H
2
S: 7.1 ppb or less,
SO
2
: 37 ppb or less, NH
3
: 423.5 ppb or less,
NO
2
: 52.3 ppb or less, O
3
: 5 ppb or less,
HCl: 6.6 ppb or less, HF: 3.6 ppb or less
Oil vapor
0.2mg/m
3
or less
Seawater (salt corrosion) If the ETERNUS AX/HX is installed on the ocean or
premises within 0.5 km from the coast, necessary
measures must be taken to prevent salt corrosion.
Noise emission
(*7)
Sound pressure level 51 dBA 69.1 dBA
Sound power level 6.9 B 7.2B
Item
ETERNUS
AX1100
ETERNUS
AX2100
ETERNUS
AX2200