EasyManua.ls Logo

Fujitsu ETERNUS DX60 S3 - ETERNUS DX60 S4 Components (Rear); Figure 10 Controllers; Table 2 Status and Meanings of each LED (Drive (Controller Enclosure))

Fujitsu ETERNUS DX60 S3
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
The LEDs turn on or blink to indicate the statuses that are listed below.
Table 2 Status and Meanings of Each LED (Drive (Controller Enclosure))
LED name LED status Meaning
DRIVE READY
(green)
The drive is in normal status.
(blinks green)
DRIVE FAULT
(amber)
The drive is in error status.
The LED light up operation was performed from the ETERNUS
CLI command line in order to identify the drive location.
ETERNUS DX60 S4 Components (Rear)
This section describes the controllers and the power supply units in the rear of the controller enclosure for the
ETERNUS DX60 S4.
Controllers
The controller contains a CPU, system memory, Battery Backup Unit (BBU), host interfaces, drive interface (DI)
ports, and LAN ports. The controller controls all operations in the ETERNUS DX.
Controllers (FC, iSCSI 10Gbit/s, iSCSI 1Gbit/s, SAS 12Gbit/s, and SAS 6Gbit/s) are available for different types of
host interfaces.
Figure 10 shows the controller. Table 3 shows the status and meanings of each LED.
Figure 10 Controllers
1234
5
1614 15
17
16
17
18 22 23
SAS 6Gbit/s SAS 12Gbit/s
FC
iSCSI 1Gbit/s
iSCSI 10Gbit/s
6
8
10711
12 13
9
19 19
19 19 19 19
2020
2121
8
9
20
21
20
21
1.
PWC port
This port is used to connect a power synchronization unit with an RS232C cable.
1. Component Names and LED Names
Controller Enclosures
14
FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic)
Copyright 2018 FUJITSU LIMITED
P3AM-9012-08ENZ0

Table of Contents

Other manuals for Fujitsu ETERNUS DX60 S3