Controllers (FC, iSCSI 10Gbit/s, iSCSI 1Gbit/s, and SAS) are available for different types of host interfaces.
Figure 12 shows the controller. Table 5 shows the status and meanings of each LED.
Figure 12 Controllers
1234
5
1412 13
15
14
15
16 20 21
SAS
FC
iSCSI 1Gbit/s
iSCSI 10Gbit/s
6
8
10711
9
17 17 17 17
1818
1919
8
9
18
19
18
19
1. PWC port
This port is used to connect a power synchronization unit with an RS232C cable.
2. DI (OUT) port
This port is used to connect a controller enclosure to a drive enclosure with a mini SAS HD cable between enclo-
sures.
3. RMT (LAN) port
This port is used for connecting a LAN cable and used for the remote support function. This port uses an RJ-45
connector.
4. MNT (LAN) port
This port is used for connecting a LAN cable and used for operation management. This port uses an RJ-45 con-
nector.
5. Host interface (CA#0)
This interface is used for connecting a controller with a server.
6. Host interface port (FC port) (CA#0, Port#0)
This port is used for connecting a controller to a server with an FC cable. This port uses a Dual LC connector.
7. Host interface port (FC port) (CA#0, Port#1)
This port is used for connecting a controller to a server with an FC cable. This port uses a Dual LC connector.
8. Host interface port (iSCSI port) (CA#0, Port#0)
This port is used for connecting a LAN cable. This port uses an RJ-45 connector.
9. Host interface port (iSCSI port) (CA#0, Port#1)
This port is used for connecting a LAN cable. This port uses an RJ-45 connector.
1. Component Names and LED Names
Controller Enclosures
18
FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic)
Copyright 2018 FUJITSU LIMITED
P3AM-9012-08ENZ0