Do
The replacement cycle for a battery is shortened if the battery is used at high tempera-
tures or the battery charges and discharges frequently.
Checking the Time to Replace the Battery
If the time to replace the battery is near, contact your maintenance engineer to re-
place the battery. If the battery is still used even after the replacement time has
passed, the performance of the ETERNUS DX60 S4 degrades because the operational
state of the cache is changed to Write Through mode.
The time to replace the battery can be checked by using the following options.
If the time to replace the battery is near, contact your maintenance engineer.
Check the time to replace the battery by using ETERNUS Web GUI or ETERNUS CLI.
If the time to replace the battery is near, a notification is sent via an e-mail or an SNMP trap message.
-
A notification is sent six months before the expiration date.
-
A notification is sent everyday for a week before the expiration date.
Related Service
Remote Support
If a possible error that may occur is detected or an error occurs when remote support service is used, the con-
tents of events are automatically sent to the remote support center and notified to the user.