56 U41221-J-Z156-1-74
The FFx-RAID Controller Module Plug-in Board Modules
Conditioning the Battery
Prior to beginning normal operation, it is recommended that you condition the
battery for maximum longevity.
I During the conditioning, the FFx-RAID controller will be in write-through
cache mode. This may slow normal operations. Therefore, schedule this
operation accordingly.
To ensure that the battery is fully charged and properly conditioned:
Ê From SAM software, select Administration/Intelligent BBU.
Ê Make sure the % Charge Level is 100. If the battery is currently charging, do
not continue until the Charge Level is 100%.
Ê Select Recondition Battery and Apply.
Refer to the SAM software documentation (see “Related publications” on
page 81) for more information.