EasyManua.ls Logo

Fujitsu PRIMERGY S60 - Server Management Status; Server Management Status LED Lights Permanently; U41221-J-Z156

Fujitsu PRIMERGY S60
99 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
74 U41221-J-Z156-1-74
Problem Solutions and Tips Troubleshooting
All the fans have failed
Ê Immediately shut down the system to prevent overheating damage in the
device.
Ê Replace the fan module (see section “Installing/Removing the Fan Module”
on page 34).
V CAUTION!
It is imperative when replacing the fan module during operation that
you take no longer than 30 seconds, since otherwise the temperature
in the storage subsystem exceeds the permissible limit values.
11.1.3 Server Management Status
In order to guarantee the server management for the PRIMERGY S60 storage
subsystem over SES (SCSI Enclosure Service), at least one of the two first HDD
modules (HDD1 and HDD2, see also section “Identification Marks and Loop
Addresses” on page 43) must be installed.
This indication can be activated manually from the ServerView. Evaluation is
performed with a later version of the storage subsystem.
11.1.3.1 Server Management Status LED lights permanently
Identification indication (can be activated manually from ServerView)
The following disturbances can have occurred:
A power supply unit has failed
Short interruption of the power supply
An out-of-limit temperature condition exists
Controller partner has failed
SES monitoring has failed
Ê Recover the disturbance as described in this section. You find further infor-
mation in the GAM software documentation.

Table of Contents

Related product manuals