76 U41221-J-Z156-1-74
Problem Solutions and Tips Troubleshooting
11.1.7 Hard Disk Drives“ dead” on System Start
Configuration of the FFx-RAID controller incorrect
Ê Correct the settings for the hard disk drives.
You will find further notes in the documentation of the configuration software.
11.1.8 Controller reports Added Hard Disk Drive as
defective
This error message can have the following cause:
FFx-RAID controller not configured for the hard disk drive
The HDD module was installed with the system switched OFF.
Ê Configure the FFx-RAID controller retroactively for the drive.
or
Ê Re-install the HDD module with the system switched ON.
If the hard disk drive is still reported as defective, the HDD module must be
replaced (see section “Hot Swap for FC HDD Modules” on page 42).