MDE-3893P Encore® and Eclipse® Series Owner’s Manual · December 2011 Page 37
Periodic Inspections Maintaining Units
Once a week, or
as notified about
a potential leak
Leaks, outside
the unit
1. Inspect the following for leaks or signs of leakage:
• Breakaways
• Couplings
• Hose outlet castings
• Hoses
• Nozzles
• Swivels
2. Look for any signs of fuel or fuel staining around
the base of the dispenser, especially at the side
columns and at the upper housing.
3. Review all documentation provided by each
component’s manufacturer for additional
inspection information.
4. If a leak is found, stop using the unit, and make
arrangements to repair the leak.
CAUTION
If you find a leak, stop using the pump/dispenser, and contact
your local ASC/CSC. Fire, explosion, or electrical shock could
result, if you continue to use a damaged pump/dispenser.
WARNING
CAUTION
Do not attempt to make these repairs yourself. Doing so could
result in severe injury or death.
WARNING
• Owner—Inspect
• ASC/CSC only—Repair
and test
Once a week or
after drive-offs
Breakaways 1. Inspect breakaways for secure connection to
hose and for any leaks.
CAUTION
If you find a leak, stop using the pump/dispenser, and contact
your local ASC/CSC. Fire, explosion, or electrical shock could
result, if you continue to use a damaged pump/dispenser.
WARNING
2. Consult the breakaway manufacturer for any
additional required inspections.
Notes:
1. If repair is required, call an ASC/CSC.
2. Some breakaways are not repairable. Check with
the ASC/CSC whether the breakaway is
repairable before the ASC/CSC attempts to
reassemble the breakaway.
3. A leak inspection within the hydraulics cabinet is
also required. See the relevant section, later in
this chapter.
CAUTION
Do not attempt to make these repairs yourself. Doing so could
result in severe injury or death.
WARNING
• Owner—Inspect
• ASC/CSC only—Repair
and test
Once a week or
as required
Wash unit
Clean with Simple Green
®
all purpose cleaner (or
equivalent). Do not wash with a high pressure hose.
Refer to
“Performing General and Component
Maintenance Inspections” on page 32.
Owner
Recommended
Frequency Components Recommended Maintenance
Who Performs the
Inspection/Repair

Table of Contents