5-7
3. Test through the Setup Menu
3. REMOTE
By selecting RT, NBDP, DMC, or NMEA and pressing [ENT] key, Remote Test or Loopback Test is
executed. MIF command, CAID outputs for the tests.
These tests disregard RT PORT and NBDP settings in SYSTEM menu.
Remote testRemote test
Remote testRemote test
Remote test
The DSC-60 transmits test data to the connected equipment and receives the response #IDxxxx (where
xxxx is the model name. For example, when FS-1562 is connected, xxxx is FS1562). The command
outputs three times, and then, if no response occurs, “NG” is displayed.
If IC-302 is connected to the DMC terminal, DMC CHECK becomes “NG”. In NMEA check, DSC-60
is connected to the NMEA terminal.
Results) Model name or NG
- RT : FS-xxxx
- NBDP : DP-6
- DMC : DMC-5
- NMEA : DSC-60
Loopback testLoopback test
Loopback testLoopback test
Loopback test
This loopback test is executed to check internal I/O circuit for each port with the peripheral unit discon-
nected. Disconnect the unit connected to the port to be checked, and put a jumper between TX and RX
lines. #CAID command is sent out through the TX line and #ID is received through the RX line if the I/
O circuit is normal. The command outputs three times, and then, if no response occurs, “NG” is dis-
played.
Results) OK or NG
- RT : OK
- NBDP : OK
- DMC : OK
- NMEA : OK
MAIN CPU
DSC-60
FS-xxxx
DP-6
#CAID
#IDFSXXXX
#CAID
#IDDP6
DMC-5
IC-302
#CAID
#CAID
#IDDMC5
#IDDSC60
DSC-60
MIF COMMAND
IEC
RT
NBDP
DMC
CONTROL/MODEM PCB
(NMEA)
TX
RX
NMEA
NBDP
DMC
RT
DSC-60
#CAID
MAIN CPU
CONTROL/MODEM PCB
Port
RT
NBDP
DMC
IEC(NMEA)
#1 - #3 , #2 - #4
Connector terminal to short
#2 - #3
#2 - #3
#1 - #3 , #2 - #4