APPENDIX 1 MENU TREE
AP-2
Data Position (Off, On),
F: Yes
Date Time (Off, On),
F: Yes
Speed (SOG) (Off, On),
F: Yes
Speed (STW) (Off, On),
F: Yes
Temp (Off, On),
F: Yes
Temp Source (NMEA, Own Temp Sensor, Own XDCR, External Temp Sensor,
External XDCR),
F: Yes
[Sonde Mark]
Sonde Mark Display*
1
(Off, LF, HF),
F: Yes
Mark Color*
1
(Red, Yellow, Light Green, Light Blue, Pink, White),
F: Yes
Width of Mark*
1
(1, 2, 3, 4),
F: Yes
[Sonde Graph]
Sonde Graph*
1
(Off, On),
F: Yes
Graph Reset*
1
(Yes, No),
F: Yes
System User User Color,
F: Yes
[User1]
Screen Layout ( , , , , ),
F: Yes
Display Mode (For three-way split: LF+HZm+HF, LZm+LF+HF,
LF+HF+MIX, HE+LF+HF, LE+LF+HF, HT+LF+HF,
LT+LF+HF; For four-way split: LZm+LF+HZm+HF,
LF+HF1+HF2+MIX, LE+HE+LF+HF,
LT+HT+LF+HF, LT+LF+HF1+HF2,
HT+LF+HF1+HF2, LT+LF+HF+MIX,
HT+LF+HF+MIX)
,
F: Yes
[User2]
Screen Layout ( , , , , )
,
F: Yes
Display Mode (
For three-way split: LF+HZm+HF, LZm+LF+HF,
LF+HF+MIX, HE+LF+HF, LE+LF+HF, HT+LF+HF,
LT+LF+HF; For four-way split: LZm+LF+HZm+HF,
LF+HF1+HF2+MIX, LE+HE+LF+HF,
LT+HT+LF+HF, LT+LF+HF1+HF2,
HT+LF+HF1+HF2, LT+LF+HF+MIX,
HT+LF+HF+MIX)
,
F: Yes
Range Range1 (16 to 9000 ft, 30 ft)
,
F: Yes
Range2 (16 to 9000 ft, 60 ft)
,
F: Yes
Range3 (16 to 9000 ft, 120 ft)
,
F: Yes
Range4 (16 to 9000 ft, 250 ft)
,
F: Yes
Range5 (16 to 9000 ft, 500 ft)
,
F: Yes
Range6 (16 to 9000 ft, 1000 ft)
,
F: Yes
Range7 (16 to 9000 ft, 1600 ft)
,
F: Yes
Range8 (16 to 9000 ft, 3000 ft)
,
F: Yes
Zoom Range (16 to 9000 ft, 16 ft)
,
F: Yes
B/L Range (16 to 9000 ft, 16 ft)
,
F: Yes
Discrim Zoom (1/2, 1/3)
,
F: Yes
Split Range (Off, On)
,
F: Yes
Auto Range (Off, On)
,
F: Yes
TX/RX TX Power,
HF TX Power (For [TruEcho CHIRP] mode: Off, 1 to 10, Auto,
F: Yes
For [Std] mode: Off, 1 to 10, 10)
HF TX Power (For [TruEcho CHIRP] mode: Off, 1 to 10, Auto,
For [Std] mode: Off, 1 to 10, 10)
TX Rate (0 to 20, 20)
,
F: Yes
Freq Control
*
2
,
F: Yes
[HF]
TX Pulse Edge
*
2
(Off, On)
,
F: Yes
TX Pulse
*
2
(1/4, 1/2, Std, ×2, Manual)
,
F: Yes
Pluse Length
*
2
(0.01 to 5.00 msec, 1.00 msec)
,
F: Yes
RX Band
*
2
(Narrow, Std, Wide, Manual)
,
F: Yes
RX Band Width
*
2
(0.2 to 25.0 kHz, 0.2 kHz)
,
F: Yes
*
1
: Available when the net sonde is connected.
*
2
: Available when the transmission mode is [Std] mode.