APPENDIX 1 MENU TREE
AP-4
[External fish finder] tab
Sounder Color Erase (0 to 50%, 0%)
Clutter (0 to 100%, For DFF1/BBDS1: 0%, For DFF3: 40%)
TVG HF TVG Level (0 to 9, For DFF1/BBDS1: 5, For DFF3: 3)
LF TVG Level (0 to 9, For DFF1/BBDS1: 5, For DFF3: 3)
STC HF STC (0 to 10, 0)
LF STC (0 to 10, 0)
Pic. Advance (Stop, 1/4, 1/2, ×1, ×2, ×4)
Smoothing (Off, 1 to 4, 3)
Display
*
1
Bottom Discrim (Off, Graphic, 4 colors, Probability)
Legend (Off, On)
Measurement ACCU-FISH (Off, On)
System TX/RX TX Power (Off, 1 to 10, 10)
TX Rate (0 to 20, 20)
Freq Control*
2
[HF]
TX Pulse*
2
(1/4, 1/2, Std, ×2, Manual)
Pluse Length*
2
(0.05 to 5.00 msec, 1.0 msec)
RX Band*
2
(Narrow, Std, Wide, Manual)
RX Band Width*
2
(0.2 to 5.0 kHz, 0.2 kHz)
[LF]
TX Pulse*
2
(1/4, 1/2, Std, ×2, Manual)
Pluse Length*
2
(0.05 to 5.00 msec, 1.0 msec)
RX Band*
2
(Narrow, Std, Wide, Manual)
RX Band Width*
2
(0.2 to 5.0 kHz, 0.2 kHz)
Calib Bottom Level HF Bottom Level (-40 to +40, +0)
LF Bottom Level (-40 to +40, +0)
Zero Line Rejection (Off, On)
Zero Line Area (0.4 to 3.0 m, 0.4 m)
Draft HF Draft (-15.0 to +50.0 ft, +0.0 ft)
LF Draft (-15.0 to +50.0 ft, +0.0 ft)
Gain ADJ HF Gain ADJ (-50 to +50, +0)
LF Gain ADJ (-50 to +50, +0)
Fish Size (-80 to +100, +0)
Stabilization
Stabilization Sensor (SC-50, SC-110, SC-30)
Stabilization Area (0 to 15 m, 15 m)
[HF]
TD fore-aft (-100.0 to +100.0 m, +0.0 m)
TD port-stbd (-100.0 to +100.0 m, +0.0 m)
ANT TD height (0.0 to 100.0 m, 0.0 m)
[LF]
TD fore-aft (-100.0 to +100.0 m, +0.0 m)
TD port-stbd (-100.0 to +100.0 m, +0.0 m)
ANT TD height (0.0 to 100.0 m, 0.0 m)
Bold Italic:Default setting
[DFF1], [DFF3] or [BBDS1]
*
1
: Shown for BBDS1.
*
2
: Shown for DFF3.