EasyManua.ls Logo

FUTABA 14SG - Sensor; Various Telemetry Sensors Setting

FUTABA 14SG
169 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
102
<Functions of Linkage Menu>
ŏ6HOHFWWKHIXQFWLRQ QDPH
DQGUHWXUQWRWKH/LQNDJH
PHQXE\WRXFKLQJWKH
RTNEXWWRQ
2UWKH
HOME/EXITEXWWRQLV
SXVKHG
<SensorTouch™>
RETURN
SENSOR
9DULRXVWHOHPHWU\VHQVRUVVHWWLQJ
This screen registers the telemetry sensors used
with the transmitter. When only one of a certain
type of sensor is used, this setting is unnecessary
and the sensor can be used by simply connecting it
to the S.BUS2 port of the transmitter.
When using 2 or more of the same kind of
sensor, they must be registered here.
ŏ6HOHFW>6(1625@LQWKH/LQNDJHPHQXDQG
DFFHVVWKHVHWXSVFUHHQ VKRZQEHORZE\
WRXFKLQJWKH571EXWWRQ
ŏ6HQVRU,':KHQPXOWLSOHVHQVRUVRIWKH
VDPHW\SHDUHQRWXVHG,'LVXQQHFHVVDU\
ŏ$VVKRZQLQWKHWDEOHEHORZDQDOWLPHWHUUHTXLUHVFRQWLJXRXVVORWV
DQGD*36VHQVRUUHTXLUHVFRQWLJXRXVVORWV,QDGGLWLRQVLQFHWKH*36
6%6*VWDUWVORWVDUHDQGVORWVDQGDUHLQKLELWHG
Assignable slot
*Altimeter, GPS, and other sensors that display a large amount of data require multiple slots.
*Depending on the type of sensor, the slot numbers that can be allocated may be limited.
>:KDWLVDVORW"@
Servos are classified by CH, but sensors are
classified in units called “slot”. There are slots
from No. 1 to No. 31.
Altitude sensors, GPS sensors and other data
sensor units may use multiple slots.
Using a sensor which uses two or more slots,
the required number of slots is automatically
assigned by setting up a start slot.
When 2 or more of the same kind of sensor are
used, the sensors themselves must allocate unused
slots and memorize that slot.
*3 slots of altitude sensor are used.
*8 slots of GPS sensor are used.
Sensor
The required
number of slots
The number which can be used as a start slot Selling area
TEMP (SBS-01T) 1 slot 1 31
Global
RPM (SBS01RM,SBS-
01RO)
1 slot 1 31
Voltage (SBS-01V) 2 slots
1,2,3,4,5,6,8,9,10,11,12,13,14,16,17,18,19,20,21,
22,24,25,26,27,28,29,30
Altitude (SBS-01A) 3 slots
1,2,3,4,5,8,9,10,11,12,13,16,17,18,19,20,21,24,2
5,26,27,28,29
GPS (SBS-01G) 8 slots 8,16,24
TEMP125-F1713 1 slot 1 31
Europe
VARIO-F1712 2 slots
1,2,3,4,5,6,8,9,10,11,12,13,14,16,17,18,19,20,21,
22,24,25,26,27,28,29,30
VARIO-F1672 2 slots
1,2,3,4,5,6,8,9,10,11,12,13,14,16,17,18,19,20,21,
22,24,25,26,27,28,29,30
GPS-F1675 8 slots 8,16,24
Q LQ WKH WDEOH EHORZ DQ DOWLPHWHU UHTXLUHV

Table of Contents

Related product manuals