117
<Model Menu (Airplane/Glider Functions)>
ŏ6HOHFWWKHIXQFWLRQ QDPH
and return to the Model
menu by touching the
RTN button.
Or the
HOME/EXIT button is
pushed.
<SensorTouch™>
RETURN
This function adjusts the pitch curve for VPP
(Variable Pitch Propeller) airplane.
*Up to 3 conditions can be set.
7KHSULRULW\LQFUHDVHVLQFRQGLWLRQĺĺRUGHU
NOTE: When VPP is not assigned to any
channel, the pitch curve is not displayed in
the model menu. In this case, assign VPP to
any channel on the function screen.
ŏ6HOHFW>3,7&859(@DWWKH0RGHOPHQX
and access the setup screen shown
below by touching the RTN button.
ŏ&XUYHUDWH
Scrolling
ŏ0RYLQJFXUVRU
ŏ6HOHFWLQJPRGH
ŏ$GMXVWLQJYDOXH
ŏ7RQH[WSDJH
PIT CURVE
>&RUUHVSRQGLQJPRGHOW\SH@$LUSODQHJHQHUDO
Setting method
Ɣ933FRQGLWLRQVHOHFWLRQ
1. Move the cursor to the # button at the top
right side of the screen and touch the RTN
button to switch to the data input mode.
6HOHFWWKH933FRQGLWLRQE\VFUROOLQJWKH
touch sensor.
*The display blinks.
Touch the RTN button to call the setting
screen and return to the cursor mode.
2. Move the cursor to the switch item and
touch the RTN button to access the selection
screen. Select the switch and set its ON
direction.
*For a description of the switch selection method, see the
description at the back of this manual.
6HWWKH933FRQGLWLRQDQGVZLWFK
*The VPP conditions can also be checked in the HOME
screen.
ƔSRLQWFXUYHVHWWLQJ
>&XUYHUDWHVHWWLQJ@
1. Move the cursor to the curve rate setting
LWHP\RXZDQWWRDGMXVWDQGWRXFKWKH571
button to switch to the data input mode.
$GMXVWWKHUDWHE\VFUROOLQJWKHWRXFKVHQVRU
,QLWLDOYDOXH
$GMXVWPHQWUDQJHa
*When the RTN button is touched for one second, the rate is
reset to the initial value.
7RXFKWKH571EXWWRQWRHQGWKHDGMXVWPHQW
and return to the cursor mode.
2. Repeat this procedure for each point.
>0RYLQJFXUYHSRLQW@
1. Move the cursor to the curve point setting
LWHP\RXZDQWWRDGMXVWDQGWRXFKWKH571
button to switch to the data input mode.
$GMXVWWKHFXUYHSRLQWE\VFUROOLQJWKHWRXFK
sensor.
,QLWLDOYDOXH3333
3
$GMXVWPHQWUDQJH8SWRLQIURQWRIWKH
DGMRLQLQJSRLQW
*When the RTN button is touched for one second, the curve
position is reset to the initial value.)
7RXFKWKH571EXWWRQWRHQGWKHDGMXVWPHQW
and return to the cursor mode.
2. Repeat this procedure for each point.
>'HOHWLQJUHWXUQLQJFXUYHSRLQW@
Move the cursor to the curve point setting
LWHP\RXZDQWWRGHOHWHUHWXUQDQGWRXFK
the RTN button for one second.
ŏ&XUYHSRLQW

Table of Contents