EasyManua.ls Logo

GE MS-6001B - Effect of Starts; Maintenance Inspections - Model Series 6000 Estimated Outage Requirements

GE MS-6001B
370 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Introduction Inspection and Maintenance — GEK 107048
I–8
Figure 1-3. Effect of Starts
4
3
2
1
5
1/1000 1/100 1/10 1/1
Starts/Fired Hour
Maintenance Factor
TYPE OF 8-HOUR
INSPECTION SHIFTS
Combustion 8
Hot Gas Path 12
Major 25
Assumptions
No Repair Time — Replacement Only
All Parts Available
All Necessary Tools Available
Crew With Average Trade Skill
Flange-To-Flange Turbine Only
Inspection Has Been Pre-Planned
Figure 1-4. Maintenance Inspections —
Model Series 6000 Estimated Outage Requirements.

Table of Contents

Related product manuals