EasyManua.ls Logo

GE MS-6001B - Transition Piece First-Stage Nozzle to Retaining Ring Clearance Checks

GE MS-6001B
370 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Combustion Inspection — Reassembly ProceduresInspection and Maintenance — GEK 107048
CI-R-9
Figure CI-R.6. Transition Piece First-Stage Nozzle to Retaining Ring Clearance Checks.
Transition
Piece
Nozzle
See Standard Practice Section 2
Approx. 5 in.
0.160
0.090
1.0 in.
0.200 Typ.
70°
3/16 in. Thru Hole
1/2
(X)1
(X)2
3(X)
4(X)
5(X)
(X)6
0.090
0.160
0.090
0.160
in.
Special Tools in This Manual

Table of Contents