DF 7500
42
TL099-01-00-15
26-03-2015
CAUSE
The plug is not correctly connected.
REMEDY
Check that the plug fits into socket seat.
CAUSE
The emergency stop button is pressed.
REMEDY
Check that the stop button is reamed. It if
doesn’t, turn the grip handle clockwise.
CAUSE
The switch is not armed.
REMEDY
Switch to ON position.
CAUSE
There are disconnected cables in the electrical
system.
REMEDY
Check the electrical system to find the
disconnected cables (make reference to the
wiring diagram), eventually contact directly
GENERAC MOBILE PRODUCTS S.r.l.
CAUSE
Fan engine does not work.
REMEDY
Replace the electrical motor. Eventually
contact directly GENERAC MOBILE
PRODUCTS S.r.l.
ANOMALY
Uneven nebulization.
CAUSE
Dirty or obstructed nozzles.
Low water pressure.
REMEDY
Nozzles to be cleaned.
Check that the pressure value on the gauge is
2 bar at least.