2.7.11
DATA LOGGING CHAPTER 7 GEODIMETER SYSTEM 600
Serial commands
If neither REG-key or Slave is selected, data output is initia-
ted from the computer by sending one of the following
commands. The command is executed upon the carriage
return. See the "Software and Data communication" manual
for a complete list of the serial commands.
Load
Load Memory. Data according to the standard format can be
loaded into the memory device.
Syntax: L<dir>=<file>
<dir>: 'I' The Area directory
'M' The Job directory
'U' The U.D.S. program directory
<file>: Is the name of the file (max 15 characters). The
file name is case sensitive.
Output
Output from memory
Syntax: O<dir>=<file>
O<dir><arg>
<dir>: 'I' The Area directory
'M' The Job directory
'U' The U.D.S. program directory
<file>: Is the name of the file (max 15 characters). The
file name is case sensitive.
<arg>: 'C' Output of the file catalog
Read
Read Instrument of measured data or data in specific labels
Syntax: RG=[<arg>][,<lbl>]
<arg>: [S] Standard output
N Name output
D Data output
V Numeric output item by item
T Test if signal from target. 300 is returned if
no signal. 301 is returned if signal.