MDE-LEDInetworkITS-server-4078V1.3
The following gure shows the different states of the NTP server:
Here is a short description of the different states:
►
just after the power-on.
► Startup
the NTP software is waiting for hardware information. It doesn’t reply to NTP clients
requests.
►
The NTP software has received both the date and the PPS from the hardware. The
phase difference is too important. The NTP software doesn’t reply to NTP clients
requests and try to reduce the phase difference.
►
The phase difference is small enough. The NTP server is now operational. It replies
to NTP clients’ requests. Moreover, it still try to reduce the phase difference if pos-
sible (tracking mode).
Startup
Idle
Rescaling
Rescaled/Tracking
Locked
Failure
Autonomous
Run autonomously