MDE-LEDInetworkITS-server-4078V1.3
4. WEB INTERFACE
1.1. Standard setup
When you click the Standard button, the network parameters and product information
are displayed.
In the top of the panel, you can control the network parameters and the WEB access
password. In the bottom of the panel, you have information about the product.
NETWORK PARAMETERS
Here are the different parameters:
IP mode
Indicate if the device works with a xed IP (set in the eld IP address) or use DHCP
protocol (the DHCP identier is set in the eld ).
IP address
Indicate the network address affected to the device. An IP address is made of four
numbers separated by a dot. Each number range from 0 to 255.

Identier to be used when the device is congured in DHCP mode. This identier
has 8 letters maximum.

Indicate the width of the network you use. For example, a network submask
255.255.255.0 indicates that only the last number change (in the example above,
address in the network can change between 192.168.10.1 to 192.168.10.254)
6
.
Gateway address
If you want the device to communicate with devices outside the local network, you
must indicate a gateway.

Check this box when you don’t have a gateway on your network (or don’t want to
use it).
6/ If you congure several devices to communicate on the same network, you must have the same network sub-
mask.
WARNING. If you click on the Submit button after changing one
or several network parameter(s), the device must restart to use the
network parameters. During the reset and a few seconds after, the
AFNOR output and the NTP output are deactivated.